1.1 This specification2 covers nominal-wall-thickness welded tubes and heavily cold worked welded tubes made from the austenitic steels listed in Table 1, with various grades
intended for such use as boiler, superheater, heat exchanger, or condenser tubes.
1.2 Grades TP304H, TP309H, TP309HCb, TP310H, TP310HCb, TP316H, TP321H, TP347H, and TP348H are modifications of Grades TP304, TP309S, TP309Cb, TP310S, TP310Cb, TP316, TP321, TP347, and TP348, and are intended for high-temperature service such as for superheaters and reheaters.
1.3 The tubing sizes and thicknesses usually furnished to this specification are 1⁄8 in. [3.2 mm] in inside diameter to 12 in. [304.8 mm] in outside diameter and 0.015 to 0.320 in. [0.4 to 8.1 mm], inclusive, in wall thickness. Tubing having other dimensions may be furnished, provided such tubes comply with all other requirements of this specification.
1.4 Mechanical property requirements do not apply to tubing smaller than 1⁄8 in. [3.2 mm] in inside diameter or 0.015 in. [0.4 mm] in thickness.
1.5 Optional supplementary requirements are provided and,when one or more of these are desired, each shall be so stated in the order.
1.6 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each
system are not exact equivalents; therefore, each system must be used independently of the other. Combining values from the two systems may result in nonconformance with the specification.
The inch-pound units shall apply unless the “M” designation of this specification is specified in the order.
1.7 The following safety hazards caveat pertains only to the test method described in the Supplementary Requirements of this specification. This standard does not purport to address all
of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific warning statement is given in Supplementary Requirement S7, NoteS7.1.
2.1 ASTM Standards: 3
A 262 Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels
A 480/A 480M Specification for General Requirements for Flat-Rolled Stainless and Heat-Resisting Steel Plate, Sheet, and Strip
A 1016/A 1016M Specification for General Requirements for Ferritic Alloy Steel, Austenitic Alloy Steel, and Stainless Steel Tubes
E 112 Test Methods for Determining Average Grain Size
E 213 Practice for Ultrasonic Examination of Metal Pipe and Tubing
E 273 Practice for Ultrasonic Examination of the Weld Zone of Welded Pipe and Tubing
E 527 Practice for Numbering Metals and Alloys (UNS)
2.2 ASME Boiler and Pressure Vessel Code:Section VIII 4
3.1 It is the responsibility of the purchaser to specify all requirements that are necessary for material ordered under this specification. Such requirements may include, but are not
limited to, the following:
3.1.1 Quantity (feet, metres, or number of lengths),
3.1.2 Name of material welded tubes (WLD) or heavily cold worked tubes (HCW),
3.1.3 Grade (Table 1),
3.1.4 Size (outside diameter and nominal wall thickness),
3.1.5 Length (specific or random),
3.1.6 Optional requirements (13.6),
3.1.7 Test report required (see Certification Section of Specification A 1016/A 1016M),
3.1.8 Specification designation, and
3.1.9 Special requirements and any supplementary requirements selected.
A Quenched in water or rapidly cooled by other methods, at a rate sufficient to prevent reprecipitation of carbides, as demonstrated by the capability of passing Practices
A 262, Practice E. The manufacturer is not required to run the test unless it is specified on the purchase order (See Supplementary Requirement S6). Note that Practices
A 262 requires the test to be performed on sensitized specimens in the low carbon and stabilized types and on specimens representative of the as-shipped condition of
the other types. In the case of low-carbon types containing 3 % or more molybdenum, the applicability of the sensitizing treatment prior to testing shall be a matter for
negotiation between the seller and purchaser.
B Quenched in water or rapidly cooled by other methods.
C A solution treating temperature above 1950°F [1065°C] may impair resistance to intergranular corrosion after subsequent exposure to sensitizing conditions in the
indicated grades. When specified by the purchaser, a lower temperature stabilization or re-solution anneal shall be used subsequent to the higher-temperature solution
anneal prescribed in this table (See Supplementary Requirement S4).
DCooled in still air, or faster.
Grade |
UNS Designation |
Tensile Strength, min, ksi [MPa] |
Yield Strength, min, ksi [MPa] |
Elongation in 2 in. or 50 mm, min, % |
Rockwell Hardness Number, max |
TP201 |
S20100 |
95 [655] |
38 [260] |
35 |
B95 |
TP202 |
S20200 |
90 [620] |
38 [260] |
35 |
B95 |
TP304 |
S30400 |
75 [515] |
30(205) |
35 |
B90 |
TP304L |
S30403 |
70 [485] |
30(205) |
35 |
B90 |
TP304H |
S30409 |
75 [515] |
25(170) |
35 |
B90 |
TP304N |
S30451 |
80 [550] |
35 [240] |
35 |
B90 |
TP309S |
S30908 |
75 [515] |
30 [205] |
35 |
B90 |
TP309H |
S30909 |
75 [515] |
30 [205] |
35 |
B90 |
TP309Cb |
S30940 |
75 [515] |
30 [205] |
35 |
B90 |
TP310S |
S31008 |
75 [515] |
30 [205] |
35 |
B90 |
TP310H |
S31009 |
75 [515] |
30 [205] |
35 |
B90 |
TP310Cb |
S31040 |
75 [515] |
30 [205] |
|
B90 |
TP316 |
S31600 |
75 [515] |
30 [205] |
35 |
B90 |
TP316L |
S31603 |
70 [485] |
25 [170] |
35 |
B90 |
TP316H |
S31609 |
75 [515] |
30 [205] |
35 |
B90 |
TP316N |
S31651 |
80 [550] |
35 [240] |
35 |
B90 |
TP317 |
S31700 |
75 [515] |
30 [205] |
35 |
B90 |
TP317L |
S31703 |
75 [515] |
30 [205] |
35 |
B90 |
TP321 |
S32100 |
75 [515] |
30 [205] |
35 |
B90 |
TP321H |
S32109 |
75 [515] |
30 [205] |
35 |
B90 |
TP347 |
S34700 |
75 [515] |
30 [205] |
35 |
B90 |
TP347H |
S34709 |
75 [515] |
30 [205] |
35 |
B90 |
|
|
|
30 [205] |
35 |
B90 |
A Not applicable to tubes less than 1⁄8 in. [3.2 mm] in outside diameter or having wall thickness below 0.015 in. [0.4 mm], or both. The tensile properties of such
small diameter or thin wall tubes shall be a matter of agreement between the manufacturer and the purchaser.
Standard/Item |
Outside Diameter |
Thickness |
Length |
||||
ASTM A249 |
|
O.D .< |
25mm |
+0.10mm |
, -0.11mm |
±10% |
O.D. < 50.8mm +3.0mm |
25mm ≦ |
O.D. ≦ |
40mm |
± 0.15mm |
|
-0mm |
||
40mm < |
O.D. < |
50mm |
±0.20mm |
|
O.D. ≧ 50.8mm +5.0mm |
||
50mm ≦ |
O.D. < |
65mm |
±0.25mm |
|
-0mm |
||
65mm ≦ |
O.D. < |
75mm |
±0.30mm |
|
|||
75mm ≦ |
O.D. ≦ |
100mm |
±0.38mm |
|
|||
100mm < |
O.D. ≦ |
200mm |
+0.38mm |
, -0.64mm |
|||
200mm < |
O.D. ≦ |
225mm |
+0.38mm |
, -1.14mm |